Heat exchanger type

Heat recovery unit or regenerator?

Ventilation units are divided into heat recovery units and regenerators. The main difference between them is the type of heat exchanger. A heat recovery unit has a plate heat exchanger, while a regenerator has a rotary heat exchanger.

The difference is that the air streams do not mix in a plate heat exchanger, while in a rotary one they do. For this reason, a rotary heat exchanger can return part of the pollutants from the extract air back into the rooms.

The efficiency of the new type of heat exchanger (hexagonal, cross counterflow) is about 90-95%, so the air supplied to the rooms does not need heating and heat losses are minimal.

Efficiency

What to look for?

The main parameter for choosing the right heat recovery unit is its efficiency, because it determines how much heat we return to the rooms and how much we lose. In addition, the lower the efficiency, the more powerful the supply air heater must be, and that requires extra energy.

Another factor that determines energy consumption – fan power. The lower the fan power, the lower the operating costs.

Comparison

Heat recovery unit comparison

Renovent Excellent
Heat recovery unitRenovent Excellent 180Renovent Excellent 300Renovent Excellent 400
Fan capacity at 150 Pa [m3/h]max. 180max. 300max. 400
Power consumption [W]18 – 869 – 66,28,6 – 98
Power consumption at 150 Pa [W]46 at 125 m3/h40 at 210 m3/h64 at 280 m3/h
Air spigots [mm]Ø125Ø160Ø180
Height [mm]600765765
Width [mm]560677677
Depth [mm]302564564
Weight [kg]253838
Max. efficiency [%]959595
Constant Flow✓✓✓
Standard bypass✓✓✓
Standard heating element–✓✓
Connection for a separate heating element–––
Humidity sensor connection✓✓✓
2-zone flow✓✓✓
Timer connection✓✓✓
PLUS version✓✓✓
Renovent Sky
Heat recovery unitRenovent Sky 150Renovent Sky 300
Fan capacity at 150 Pa [m3/h]max. 150max. 300
Power consumption [W]8,7 – 77,811 – 72
Power consumption at 150 Pa [W]*51 at 210 m3/h
Air spigots [mm]Ø125Ø150/Ø160
Height [mm]200310
Width [mm]660644
Depth [mm]10001185
Weight [kg]24,537
Max. efficiency [%]9595
Constant Flow✓✓
Standard bypass✓✓
Standard heating element✓–
Connection for a separate heating element–✓
Humidity sensor connection–✓
2-zone flow––
Timer connection––
PLUS version✓✓