How to choose a ventilation system?
Heat recovery unit or regenerator, efficiency and energy consumption.
Send inquiryHeat recovery unit or regenerator?
Ventilation units are divided into heat recovery units and regenerators. The main difference between them is the type of heat exchanger. A heat recovery unit has a plate heat exchanger, while a regenerator has a rotary heat exchanger.
The difference is that the air streams do not mix in a plate heat exchanger, while in a rotary one they do. For this reason, a rotary heat exchanger can return part of the pollutants from the extract air back into the rooms.
The efficiency of the new type of heat exchanger (hexagonal, cross counterflow) is about 90-95%, so the air supplied to the rooms does not need heating and heat losses are minimal.
What to look for?
The main parameter for choosing the right heat recovery unit is its efficiency, because it determines how much heat we return to the rooms and how much we lose. In addition, the lower the efficiency, the more powerful the supply air heater must be, and that requires extra energy.
Another factor that determines energy consumption – fan power. The lower the fan power, the lower the operating costs.
Heat recovery unit comparison
| Heat recovery unit | Renovent Excellent 180 | Renovent Excellent 300 | Renovent Excellent 400 |
|---|---|---|---|
| Fan capacity at 150 Pa [m3/h] | max. 180 | max. 300 | max. 400 |
| Power consumption [W] | 18 – 86 | 9 – 66,2 | 8,6 – 98 |
| Power consumption at 150 Pa [W] | 46 at 125 m3/h | 40 at 210 m3/h | 64 at 280 m3/h |
| Air spigots [mm] | Ø125 | Ø160 | Ø180 |
| Height [mm] | 600 | 765 | 765 |
| Width [mm] | 560 | 677 | 677 |
| Depth [mm] | 302 | 564 | 564 |
| Weight [kg] | 25 | 38 | 38 |
| Max. efficiency [%] | 95 | 95 | 95 |
| Constant Flow | ✓ | ✓ | ✓ |
| Standard bypass | ✓ | ✓ | ✓ |
| Standard heating element | – | ✓ | ✓ |
| Connection for a separate heating element | – | – | – |
| Humidity sensor connection | ✓ | ✓ | ✓ |
| 2-zone flow | ✓ | ✓ | ✓ |
| Timer connection | ✓ | ✓ | ✓ |
| PLUS version | ✓ | ✓ | ✓ |
| Heat recovery unit | Renovent Sky 150 | Renovent Sky 300 |
|---|---|---|
| Fan capacity at 150 Pa [m3/h] | max. 150 | max. 300 |
| Power consumption [W] | 8,7 – 77,8 | 11 – 72 |
| Power consumption at 150 Pa [W] | * | 51 at 210 m3/h |
| Air spigots [mm] | Ø125 | Ø150/Ø160 |
| Height [mm] | 200 | 310 |
| Width [mm] | 660 | 644 |
| Depth [mm] | 1000 | 1185 |
| Weight [kg] | 24,5 | 37 |
| Max. efficiency [%] | 95 | 95 |
| Constant Flow | ✓ | ✓ |
| Standard bypass | ✓ | ✓ |
| Standard heating element | ✓ | – |
| Connection for a separate heating element | – | ✓ |
| Humidity sensor connection | – | ✓ |
| 2-zone flow | – | – |
| Timer connection | – | – |
| PLUS version | ✓ | ✓ |