MK KOLEKT MULTI chimney cross-section – ceramic flue with thermal insulation wool, tee and door

MK KOLEKT multi

The MK KOLEKT multi chimney system is suitable not only for modern solid and liquid fuel condensing boilers (where the flue gas temperature is below 200 °C) but also for modern insulation systems.

The three-layer system, fully insulated with mineral wool, meets the highest requirements. The ceramic elements with mineral wool insulation are centred with centring rings. The air gap between the mineral wool and the expanded clay concrete block is used for air supply.

The ceramic elements, made in Germany, meet the highest W3G class requirements. The ceramic chimney elements are resistant to soot fire, even in wet operation, as well as to low and high temperatures. The ceramic liner has a smooth surface and high resistance to condensate (resistant to aggressive corrosive factors).

MK KOLEKT multi ceramic elements are highly resistant to mechanical impact and can be drilled or cut without fear of the ceramics cracking, with no extra relief cuts needed. When ordering the MK KOLEKT multi chimney system, you can order ceramic elements with mineral wool already fitted.

Installing the chimney system is simple, easy and quick. Installation is even simpler thanks to the longer ceramic elements, which reduce the number of joints. The quality of the MK KOLEKT multi chimney system is confirmed by the CE certificates of conformity issued.

Chimney for a passive house

The design of a chimney used in passive houses differs from standard chimneys. Standard ceramic system flues do not meet the requirements, because in these systems the air for ventilating the ceramics is taken from the room.

New-generation appliances suitable for passive houses differ from earlier ones in their airtightness: the ceramics no longer need to be ventilated, and air is supplied to the heating appliance through the air gap between the block and the insulation.

The wall of the ceramic element is thinner: a conventional ceramic flue wall is roughly one and a half to two centimetres thick, while that of a modern passive house chimney is much thinner.

The chimney systems are not affected by moisture, and there are no conditions for a dew point to form. These properties give ceramic flues an advantage over steel systems.

Both types of systems are suitable for an A++ class building, but it is important to pay attention to airtightness and the formation of a “cold bridge”. When installing stainless steel flues in a passive house, you will certainly face the “cold bridge” problem.

Appliances connected to flue systems must have the same properties, which means they must be airtight. Conventional fireplaces that took combustion air from the room are not suitable for A class buildings either.

Buildings of this class require certified appliances with an outdoor combustion air connection and a secondary combustion system.

MK KOLEKT flue system with cleanout, tee and condensate collection – vertical section

Characteristics of modular chimney systems

MK KOLEKT multi
Quickly creates good draught; acid-resistant; resistant to high temperatures.
Suitable for boilers using various fuels (firewood, coal, gas, pellets, etc.).
Suitable for use with room-sealed boilers and condensing boilers, and can also be used as a concentric condensing chimney system where a separate air supply to the heating appliance is required.
The ceramic flue pipes are resistant to soot fire and meet the requirements of the highest W3G class.
The ceramic liner is designed for operation at high and low temperatures (from 60 to 600 °C).
The ceramic liner has a smooth surface and high resistance to condensate.
Ceramic liners are made in various diameters (mm): Ø120; Ø140; Ø160; Ø180; Ø200; Ø250; Ø300.
A thin-walled ceramic liner that is just as strong as a thick-walled ceramic liner.
The insulated ceramic pipe is centred in the expanded clay concrete block with a centring ring.
The centring rings create an air gap for additional air supply.
Fewer joints thanks to longer ceramic elements.
Fire resistance – 90 min.
Quick and easy installation.
The products are certified.

MK KOLEKT multi structure

The MK KOLEKT MULTI three-layer chimney system consists of expanded clay concrete or ceramic blocks, mineral wool, ceramic elements and other accessories. A complete chimney system kit includes: chimney blocks, mineral wool, centring rings, ceramic end cap, liners, cleanout, tee and ceramic adhesive. We also offer a chimney top kit, a stainless steel adapter and a dry masonry mix.

Accessories

Accessories supplied with the MK KOLEKT multi chimney system kit:

  • Cleanout door;
  • Centring rings.

Accessories supplied on request:

  • Chimney top consisting of a chimney cover plate and a rain cap. You can choose between a stainless steel cover plate with a rain cap and a stainless steel cover plate with a cowl. For a passive house, we recommend a cover plate with air intake;
  • Stainless steel connection adapter. For a passive house, we recommend an adapter with air supply;
  • Dry masonry mix.

*Accessories ordered separately
**Accessories included when buying an MK KOLEKT chimney kit and ordering a chimney top kit

Chimney cover with rain cap

Stainless steel chimney cover

Chimney cover with cowl

Chimney cap

Cover plate with air intake

Chimney cap

Cleanout door

Cleanout door

Centring ring

Centring ring

Masonry mix

MK KOLEKT Mix masonry mortar

Connection adapter*

Connection adapter

Connection adapter*

Connection adapter

Stencils**

Templates for marking openings

Ceramic elements

MK KOLEKT German ceramics

Ceramic elements included in the MK KOLEKT multi chimney system kit:

  • Condensate collector (base cap);
  • Cleanout;
  • Tee;
  • Chimney liners.

The ceramic elements are connected using joints specially formed in them. The joints are secured with the ceramic adhesive supplied with the kit. All ceramic elements can be supplied with mineral wool already fitted on them.

GERMAN ceramic Hart Keramik chimney components are supplied with KONEKT

90° tee

MK KOLEKT multi chimney system
Model Height (cm) Weight (kg) Per pallet (pcs)
RRO300M 100 32 6
RRO250M 100 22,1 8
RRO200M 100 22 12
RRO180M 100 22 12
RRO160M 100 15,6 15
RRO140M 100 15,6 20
RRO120M 100 10,2 20

Cleanout

Ceramic cleanout
Model Height (cm) Weight (kg) Per pallet (pcs)
PTO300M 66,5 22,1 6
PTO250M 66,5 15,1 8
PTO200M 66,5 10,2 12
PTO180M 66,5 9,9 15
PTO160M 66,5 9,3 15
PTO140M 66,5 8,4 24
PTO120M 66,5 7 28

Ceramic liner

Ceramic chimney liner
Model Height (cm) Weight (kg) Per pallet (pcs)
KLR300M 100 29,95 6
KLR250M 100 20,45 8
KLR200M 100 15,2 17
KLR180M 100 14,05 20
KLR160M 100 12,4 20
KLR140M 100 10,6 24
KLR120M 100 9,85 28

Condensate collector

Condensate collector
Model Height (cm) Weight (kg) Per pallet (pcs)
SO250M 50 12 8
SO200M 50 9 12
SO180M 50 8 15
SO160M 50 7,5 15
SO140M 50 7 24
SO120M 50 6 28

Other elements of the MK KOLEKT multi chimney system

Other chimney system elements supplied with the standard MK KOLEKT chimney system kit:

  • Ceramic adhesive.

The ceramic chimney elements are secured with special ceramic adhesive. A tub of adhesive is included in the price of the MK KOLEKT chimney kit.

Ceramic adhesive

Ceramic adhesive

Blocks

Expanded clay concrete chimney block options:

  • Chimney block without ventilation ducts;
  • Chimney block with 2 ventilation ducts.

 

Optional ceramic chimney block:

  • Chimney block without ventilation ducts;

 

Expanded clay concrete ventilation block options:

  • Ventilation block with 1 ventilation duct;
  • Ventilation block with 2 ventilation ducts;
  • Ventilation block with 3 ventilation ducts;
  • Ventilation block with 4 ventilation ducts.

 

Both chimney blocks and ventilation blocks can be placed next to each other if the situation allows. Thanks to their dimensions, the blocks are easy to lay side by side.

Chimney blocks

Chimney block without ventilation
Chimney block without ventilation

Dimensions (cm): 35x35x24

Weight (kg): 12

Per pallet (pcs): 63

Chimney block with 2 vent. ducts
Chimney block with 2 ventilation ducts

Dimensions (cm): 56x36x24

Weight (kg): 18

Per pallet (pcs): 42

Chimney block without ventilation
MK KOLEKT multi ceramic block

Dimensions (cm): 36x36x24 / 42x42x42

Weight (kg): 21 / 27

Per pallet (pcs): –

Ventilation blocks

1-duct ventilation block
Single-duct ventilation block

Dimensions (cm): 25x25x24

Weight (kg): 9

Per pallet (pcs): 90

2-duct ventilation block
Two-duct ventilation block

Dimensions (cm): 36x25x24

Weight (kg): 12.5

Per pallet (pcs): 84

3-duct ventilation block
Three-duct ventilation block

Dimensions (cm): 52x25x24

Weight (kg): 18

Per pallet (pcs): 36

4-duct ventilation block
Four-duct ventilation block

Dimensions (cm): 50x36x24

Weight (kg): 27

Per pallet (pcs): 24

MK KOLEKT multi installation tips

1. Joining the ceramic liners

Ceramic liner with sealing joint – MK KOLEKT chimney part drawing

When installing the ceramic elements, pay attention to their joints. The ceramic pipes connect to each other by means of specially moulded joints. Each ceramic pipe always fits into the ceramic pipe below it. The joint with the inner protrusion must always be at the bottom. The upper part of the pipe has the joint with the inner recess.

2. Distance to structures

MK KOLEKT chimney block with insulation installation diagram – structure and brackets
Chimney insulation solution – drawing of the junction of mineral wool and timber structures

Openings through the roof or floor slabs must be at least 2 – 3 cm away from the block walls on all sides, and at least 5 cm if the structures the chimney passes through are combustible. The gaps can be filled with mineral wool.

3. Ceramic connection and cleanout tees

  • When cutting openings for the connection tee or cleanout in the block, leave a slightly larger gap to the ceramic parts so that the ceramics do not touch the block walls and have room to move.
  • We recommend buying a connection adapter that fits over the branch of the connection tee. If you use an adapter that slides inside, make sure that the heat-resistant rope used to fill the air gap is not too stiff.

MK KOLEKT multi installation instructions

Careful installation ensures long and flawless operation of the chimney system.

Before you start installing the chimney, you need to know which way the cleanout door will face and at what height the connection tee will be. If the chimney has an additional ventilation duct alongside, plan the height of the ventilation duct opening. The free-standing part of the chimney must be structurally reinforced. For this you can also use the round holes in the corners of the block: insert reinforcement bars into them and fill them with concrete.

  1. Build the chimney on a pre-prepared concrete foundation.
  2. Join the chimney blocks with cement or cement-lime mortar.
  3. Apply the mortar to the walls of the chimney blocks (the ventilation ducts in the corners of the block and the mineral wool must not come into contact with the mortar).
  4. The ceramic elements are joined with a special acid-resistant sealant supplied in a bucket. The edge of the ceramic pipe must be clean before applying the sealant. Apply the sealant to the pre-moistened edge of the pipe.
  5. Connect the condensate container to the sewer.

If installation is carried out with a break of several days, protect the inside of the chimney from moisture.

1. Preparing the plinth

MK KOLEKT chimney foundation build-up – concrete slab, expanded clay concrete block and filling
  1. Lay insulating material on the pre-formed foundation;
  2. Form a 20-30 cm plinth of concrete or masonry;
  3. Or fill the first chimney block with concrete.

2. Preparing the chimney base

MK KOLEKT chimney block and ceramic liner installation steps with tee and cleanout
  1. Using the template, mark the required opening size on the block wall;
  2. Cut out the marked opening in the bottom of the block for the condensate pipe;
  3. Place the block on the plinth coated with mortar;
  4. Place the condensate collector with the pipe inside the block;
  5. Using the template, mark the required opening size on the block wall;
  6. Cut the opening with an angle grinder;
  7. Place the block on the previously laid block coated with mix;

3. Installing the cleaning tee/cleanout

MK KOLEKT chimney block and ceramic liner installation stages with tee and cleanout
  1. Using the template, mark the required opening size on the block wall;
  2. Cut the opening with an angle grinder;
  3. Place the block with the cut opening onto the block below with masonry mortar;
  4. Fit the centring ring on the cleanout;
  5. Apply acid-resistant sealant/adhesive to the cleaned edge of the liner;
  6. Insert the cleaning tee/cleanout;
  7. Wipe excess sealant off the inner pipe joint;
  8. Using the template, mark the required opening size on the block wall;
  9. Cut the opening with an angle grinder;
  10. Lay the block on the block with masonry mix.

4. Installing the connection tee

MK KOLEKT chimney block installation with ceramic tee and adapter elements
  1. Lay the block on the block with masonry mix;
  2. Using the template, mark the required opening size on the block;
  3. Place the block with the cut opening onto the block coated with mortar;
  4. Fit the centring ring onto the connection tee;
  5. Apply acid-resistant sealant/adhesive to the cleaned and moistened edge;
  6. Insert the connection tee;
  7. Wipe excess sealant off the inner pipe joint;
  8. Using the template, mark the required opening size on the next block;
  9. Lay the block with the cut-out opening on the block with masonry mix.

Connecting the tee requires a special adapter. Never fit an ordinary liner into the branch of the tee!

5. Standard installation sequence

MK KOLEKT chimney ceramic liner and block assembly – tee and sealing details
  1. Fit the centring ring on the ceramic liner;
  2. Apply acid-resistant sealant/adhesive to the cleaned and moistened pipe edge;
  3. Insert the ceramic pipe;
  4. Lay the blocks on the installation mix;
  5. Wipe excess sealant off the inner liner joint.

Repeat the sequence until the chimney is complete.

6. Finishing the chimney

Installing the MK KOLEKT chimney ceramic liner into the expanded clay concrete block – first steps
  1. The mineral wool in the last block must be shorter, so trim it;
  2. Before inserting the last pipe, shorten it with an angle grinder;
  3. Clean and moisten the pipe edge and apply acid-resistant sealant/adhesive;
  4. Insert the ceramic pipe.

7. Fixing the chimney top

MK KOLEKT chimney cover plate with protective hood and plate – detail of the chimney top
  1. The anchor is screwed in with a hex bolt into the fixing holes in the expanded clay concrete block;
  2. Do not screw the anchor in all the way, leave about 1 cm above the block;
  3. The chimney cover plate is placed on the chimney block and fixed with a bolt through the cover plate.