Ceramic chimneys - MK KOLEKT

A modular chimney system is a chimney system made up of several main components: expanded clay concrete blocks, mineral wool and ceramic elements. We can offer you two types of ceramic elements: universal ceramics and ceramics that are especially suitable where high temperatures act for long periods, e.g. a bathhouse or sauna.

The MK KOLEKT chimney system with universal ceramics is used not only with modern solid and liquid fuel condensing boilers (when the flue gas temperature is below 200 °C), but also in modern insulation systems. The three-layer system, fully insulated with mineral wool, meets the highest requirements. The ceramic elements, made in Germany, meet the strict A1N1/B4N1 class requirements. The ceramic chimney elements are resistant to soot fire, as well as to low and high temperatures (60 °C - 600 °C). The German ceramic liner has a smooth surface and high resistance to condensate (it withstands aggressive corrosive factors). The MK KOLEKT system uses special insulation that fills the air gap between the ceramic elements and the expanded clay concrete chimney blocks. Installing the MK KOLEKT chimney system is simple, easy and fast. The MK KOLEKT chimney system with universal ceramics consists of: light and strong expanded clay concrete blocks, heat-resistant mineral wool insulation filling the air gap between the block and the ceramic elements, ceramic elements (condensate collector, cleanout, connection tee, liners), adhesive for ceramic elements, other accessories (doors, grilles, chimney top finish).

Unlike MK KOLEKT with universal ceramics, MK KOLEKT with AT ceramics offers increased resistance to temperature changes. This chimney system is used with heating appliances that burn solid fuel. German AT ceramics are not produced by "extrusion" but by pressing much drier materials (mostly fireclay). Instead of 18% moisture in the production material, the material for AT ceramics contains only 4% moisture. This mass is poured into moulds and compressed with great force by a hydraulic press. The result is ceramic elements that are especially suitable where specialised chimneys are needed that operate at high working temperatures for long periods. The MK KOLEKT chimney system with AT ceramics consists of: light and strong expanded clay concrete blocks, heat-resistant mineral wool insulation filling the air gap between the block and the ceramic elements, ceramic elements (cleanout, connection tee, liners), adhesive for ceramic elements, other accessories (doors, grilles, chimney top finish).

MK KOLEKT chimney components – all flue parts from ceramic liners to blocks and insulation

Characteristics of modular chimney systems

MK KOLEKT and MK KOLEKT AT
Quickly creates good draught; acid-resistant; resistant to high temperatures.
Suitable for boilers using various fuels (firewood, coal, gas, pellets, etc.). Suitable for solid fuel boilers (firewood, coal, pellets, etc.).
Casing – expanded clay concrete block with a compressive strength of 3.0 MPa. The block is lightweight and has high compressive strength. Casing – expanded clay concrete block. The block is lightweight and has high compressive strength.
The ceramic flue pipes are resistant to soot fire and meet A1N1/B4N1 class requirements. The ceramic flue pipes are resistant to soot fire and meet A1N1 class requirements.
The ceramic liner is designed for operation at high and low temperatures (from 60 to 600 °C). The ceramic liner is designed for operation at high temperatures (from 200 °C).
The ceramic liner has a smooth surface.
Ceramic liners are produced in various diameters (mm): Ø140; Ø160; Ø180; Ø200; Ø250; Ø300; Ø350; Ø400. Ceramic liners are produced in various diameters (mm): Ø160; Ø180; Ø200.
The gap between the ceramic pipe and the expanded clay concrete block is filled with special mineral wool along the full height of the chimney. Has a ventilation system for the mineral wool.
Fire resistance – 90 min.
The chimney is installed either against an external wall or inside the building and takes up very little space.
Quick and easy installation.
The products are certified.

MK KOLEKT structure

The three-layer MK KOLEKT chimney system consists of expanded clay concrete blocks, mineral wool, ceramic elements and other accessories. The standard chimney system kit includes expanded clay concrete blocks, mineral wool to fill the air gap between the blocks and the ceramic elements, a ceramic condensate collector, liners, a cleanout, a tee, ceramic adhesive, a cleanout door and ventilation grilles. We also offer a chimney top kit, a stainless steel adapter, additional ceramic cleanout doors, dry masonry mix and a mineral wool board for the tee branch.

Accessories

Accessories supplied with the standard MK KOLEKT chimney system kit:

  • Ventilation grilles, fitted at the bottom of the chimney at the condensate collector;
  • Cleanout door.

 

Accessories supplied on request:

  • Chimney top consisting of a chimney cover and a rain cap. You can choose between a stainless steel cover with a rain cap and a stainless steel cover with a cowl. Instead of the stainless steel chimney top cover, a concrete cover can be chosen;
  • Stainless steel connection adapter;
  • Ceramic doors used together with standard doors;
  • Mineral wool board for the tee branch, to cover the opening cut in the block for the connection tee;
  • Dry masonry mix;

*Accessories ordered separately
**Accessories included when buying an MK KOLEKT chimney kit and ordering a chimney top kit

Chimney cover with rain cap

Stainless steel chimney cover

Chimney cover with cowl

Chimney cap

- or -

Concrete slab

Concrete chimney cover

Cowl

Chimney cowl (deflector)

Cleanout door

Cleanout door

Ventilation grilles

Ventilation grille

Masonry mix*

MK KOLEKT Mix masonry mortar

Mineral wool board*

Mineral wool board for the tee branch

Connection adapter*

Connection adapter

Ceramic cleanout door*

Ceramic cleanout door

Stencils**

Templates for marking openings

Ceramic elements

MK KOLEKT German ceramics

Ceramic elements included in the standard MK KOLEKT chimney system kit:

  • Condensate collector (base cap);
  • Cleanout;
  • One of two types of tee;
  • Chimney liners.

The ceramic elements are joined using specially moulded joints. The joints are secured with the ceramic adhesive supplied with the kit.

Ceramic elements supplied on request:

  • Ceramic doors used together with standard doors.

GERMAN ceramic Hart Keramik chimney components are supplied with KONEKT

90° tee

Ceramic tee 90°
Model Height (cm) Weight (kg) Per pallet (pcs)
RRO40066644
RRO35066556
RRO30066418
RRO250663212
RRO2006615,620
RRO1806614,924
RRO1606612,924
RRO1406611,236

45° tee

Ceramic tee 45°
Model Height (cm) Weight (kg) Per pallet (pcs)
RRO400/456676—
RRO350/456669—
RRO300/456650—
RRO250/456641—
RRO200/456619,216
RRO180/456618,516
RRO160/456614,220
RRO140/456612,520

Cleanout

Ceramic cleanout
Model Height (cm) Weight (kg) Per pallet (pcs)
PTO40066548
PTO35066518
PTO300663412
PTO250663016
PTO2006615,930
PTO1806614,230
PTO1606612,330
PTO140661248

Ceramic liner

Ceramic chimney liner
Model Height (cm) Weight (kg) Per pallet (pcs)
KLR4003326,415
KLR3503324,520
KLR3003317,130
KLR250331540
KLR200337,245
KLR180336,560
KLR160336,275
KLR14033590

Condensate collector

Condensate collector
Model Height (cm) Weight (kg) Per pallet (pcs)
SO4001647,6—
SO3501638,5—
SO300162716
SO2501812,412
SO20/18186,160
SO16/14184,260

Ceramic cleanout door*

Ceramic cleanout door
Model Height (cm) Weight (kg) Per pallet (pcs)
KKS19019×26—126
KKS14014×26—126

Other elements of the MK KOLEKT multi chimney system

Other chimney system elements supplied with the standard MK KOLEKT chimney system kit:

  • Ceramic adhesive.

The ceramic chimney elements are secured with special ceramic adhesive. A tub of adhesive is included in the price of the MK KOLEKT chimney kit.

Ceramic adhesive

Ceramic adhesive

Mineral wool

Mineral wool for chimney insulation

Expanded clay concrete blocks

Expanded clay concrete chimney block options:

  • Chimney block without ventilation ducts;
  • Chimney block with 2 ventilation ducts.

 

Expanded clay concrete ventilation block options:

  • Ventilation block with 1 ventilation duct;
  • Ventilation block with 2 ventilation ducts;
  • Ventilation block with 3 ventilation ducts;
  • Ventilation block with 4 ventilation ducts.

 

Both chimney blocks and ventilation blocks can be placed next to each other if the situation allows. Thanks to their dimensions, the blocks are easy to lay side by side.

Chimney blocks

Chimney block without ventilation
Chimney block without ventilation

Dimensions (cm): 36x36x24

Weight (kg): 12

Per pallet (pcs): 63

Chimney block with 1 vent. duct
Chimney block with a ventilation duct

Dimensions (cm): 50x36x24

Weight (kg): 18

Per pallet (pcs): 24

Chimney block with 2 vent. ducts
Chimney block with 2 ventilation ducts

Dimensions (cm): 56x36x24

Weight (kg): 18

Per pallet (pcs): 42

Ventilation blocks

1-duct ventilation block
Single-duct ventilation block

Dimensions (cm): 25x25x24

Weight (kg): 9

Per pallet (pcs): 90

2-duct ventilation block
Two-duct ventilation block

Dimensions (cm): 36x25x24

Weight (kg): 12.5

Per pallet (pcs): 84

3-duct ventilation block
Three-duct ventilation block

Dimensions (cm): 52x25x24

Weight (kg): 18

Per pallet (pcs): 36

4-duct ventilation block
Four-duct ventilation block

Dimensions (cm): 50x36x24

Weight (kg): 27

Per pallet (pcs): 24

MK KOLEKT installation tips

1. Joining the ceramic liners

Ceramic liner with sealing joint – MK KOLEKT chimney part drawing

When installing the ceramic elements, pay attention to their joints. The ceramic pipes connect to each other by means of specially moulded joints. Each ceramic pipe always fits into the ceramic pipe below it. The joint with the inner protrusion must always be at the bottom. The upper part of the pipe has the joint with the inner recess.

2. Insulation layer joints

Examples of ceramic chimney liner installation direction – correct and incorrect insertion

When fitting the mineral wool, pay attention to where the joints between two pieces of wool are located. The joint between the pieces must not face the ventilation openings of the chimney block. The joint between two pieces of mineral wool must face one of the 4 walls of the chimney block, so that the mineral wool wraps the ceramic chimney liners correctly and works as intended.

3. Distance to structures

MK KOLEKT chimney block with insulation installation diagram – structure and brackets
Chimney insulation solution – drawing of the junction of mineral wool and timber structures

Openings through the roof or floor slabs must be at least 2 – 3 cm away from the block walls on all sides, and at least 5 cm if the structures the chimney passes through are combustible. The gaps can be filled with mineral wool.

3. Ceramic connection and cleanout tees

  • When cutting openings for the connection tee or cleanout in the block, leave a slightly larger gap to the ceramic parts so that the ceramics do not touch the block walls and have room to move.
  • We recommend buying a connection adapter that fits over the branch of the connection tee. If you use an adapter that slides inside, make sure that the heat-resistant rope used to fill the air gap is not too stiff.

MK KOLEKT multi installation instructions

Careful installation ensures long and flawless operation of the chimney system.

Before you start installing the chimney, you need to know which way the cleanout door will face and at what height the connection tee will be. If the chimney has an additional ventilation duct alongside, plan the height of the ventilation duct opening. The free-standing part of the chimney must be structurally reinforced. For this you can also use the round holes in the corners of the block: insert reinforcement bars into them and fill them with concrete.

  1. Build the chimney on a pre-prepared concrete foundation.
  2. Join the chimney blocks with cement or cement-lime mortar.
  3. Apply the mortar to the walls of the chimney blocks (the ventilation ducts in the corners of the block and the mineral wool must not come into contact with the mortar).
  4. The ceramic elements are joined with a special acid-resistant sealant supplied in a bucket. The edge of the ceramic pipe must be clean before applying the sealant. Apply the sealant to the pre-moistened edge of the pipe.
  5. Connect the condensate tray to the sewer.

If installation is carried out with a break of several days, protect the inside of the chimney from moisture.

1. Preparing the plinth

MK KOLEKT chimney foundation build-up – concrete slab, expanded clay concrete block and filling
  1. Lay insulating material on the pre-formed foundation;
  2. Form a 20-30 cm plinth of concrete or masonry;
  3. Or fill the first chimney block with concrete.

2. Preparing the chimney base

Assembling MK KOLEKT chimney blocks with end caps and grilles – installation steps
  1. Using the template, mark the required opening size on the block wall;
  2. Cut out the marked opening in the lower part of the block. The ventilation grille will later be fitted into this opening;
  3. Place the block on the plinth coated with mortar;
  4. Place the condensate collector (end cap) inside the block. Set the end cap on mortar and point the drain pipe towards the opening.

3. Installing the cleaning tee/cleanout

MK KOLEKT chimney block and ceramic liner assembly steps with cleanout and door
  1. Using the template, mark the required opening size on the block wall;
  2. Cut the opening with an angle grinder;
  3. Place the block with the cut opening onto the block below with masonry mortar;
  4. Insert the mineral wool into the block and trim it so that it does not block the openings;
  5. Apply acid-resistant sealant/adhesive to the cleaned edge of the condensate tray;
  6. Insert the cleaning tee/cleanout;
  7. Place the next block onto the block with masonry mortar and insert the mineral wool.

4. Installing the connection tee

MK KOLEKT chimney block and ceramic tee installation steps with adapter parts
  1. Using the template, mark the required opening size on the block;
  2. Place the block with the cut opening onto the block coated with mortar;
  3. Insert the mineral wool and trim it so that it does not block the openings;
  4. Apply acid-resistant sealant/adhesive to the cleaned and moistened edge;
  5. Insert the connection tee;
  6. Wipe excess sealant off the inner pipe joint;
  7. Place the next block onto the block with masonry mortar and insert the cut mineral wool.

Connecting the tee requires a special adapter. Never fit an ordinary liner into the branch of the tee!

5. Standard installation sequence

MK KOLEKT chimney block and ceramic liner installation steps with mineral wool insulation
  1. Place the block on the mortar;
  2. Insert the mineral wool into the block;
  3. Apply acid-resistant sealant/adhesive to the cleaned and moistened pipe edge;
  4. Insert the ceramic pipe;
  5. Wipe excess sealant off the inner liner joint.

Repeat the sequence until the chimney is complete.

6. Finishing the chimney

Inserting the MK KOLEKT ceramic chimney liner into the block – first assembly stages
  1. The mineral wool in the last block must be shorter, so trim it;
  2. Before inserting the last pipe, shorten it with an angle grinder;
  3. Clean and moisten the pipe edge and apply acid-resistant sealant/adhesive;
  4. Insert the ceramic pipe.

7. Fixing the chimney top

MK KOLEKT chimney cover plate with protective hood and plate – detail of the chimney top
  1. The anchor is screwed in with a hex bolt into the fixing holes in the expanded clay concrete block;
  2. Do not screw the anchor in all the way, leave about 1 cm above the block;
  3. The chimney cover plate is placed on the chimney block and fixed with a bolt through the cover plate.